This module provides tools to convert eDisGo representation of the network
topology and timeseries to PowerModels network data format and to retrieve results from
PowerModels OPF in PowerModels network data format to eDisGo representation.
Call :func:`to_powermodels` to retrieve the PowerModels network container and
:func:`from_powermodels` to write OPF results to edisgo object.
"""
import json
import logging
import math
from copy import deepcopy
import numpy as np
import pandas as pd
import pypsa
from edisgo.flex_opt import exceptions
from edisgo.flex_opt.costs import line_expansion_costs
from edisgo.tools.tools import calculate_impedance_for_parallel_components
logger = logging.getLogger(__name__)
[docs]
def to_powermodels(
edisgo_object,
s_base=1,
flexible_cps=None,
flexible_hps=None,
flexible_loads=None,
flexible_storage_units=None,
opf_version=1,
):
"""
Convert eDisGo representation of the network topology and timeseries to
PowerModels network data format.
Parameters
----------
edisgo_object : :class:`~.EDisGo`
s_base : int
Base value of apparent power for per unit system.
Default: 1 MVA.
flexible_cps : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all charging points that allow for flexible charging.
flexible_hps : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all heat pumps that allow for flexible operation due to an
attached heat storage.
flexible_loads : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible loads that allow for application of demand side
management strategy.
flexible_storage_units : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible storages. Non-flexible storage units operate to
optimize self consumption.
Default: None.
opf_version : int
Version of optimization models to choose from. Must be one of [1, 2, 3, 4].
For more information see :func:`edisgo.opf.powermodels_opf.pm_optimize`.
Default: 1.
Returns
-------
(dict, dict)
First dictionary contains all network data in PowerModels network data
format. Second dictionary contains time series of HV requirement for each
flexibility retrieved from overlying_grid component of edisgo object and
reduced by non-flexible components.
"""
if opf_version in [2, 3, 4]:
opf_flex = ["curt"]
else:
opf_flex = []
if flexible_cps is None:
flexible_cps = np.array([])
if flexible_hps is None:
flexible_hps = np.array([])
if flexible_loads is None:
flexible_loads = np.array([])
if flexible_storage_units is None:
flexible_storage_units = np.array([])
# Append names of flexibilities for OPF
for flex, loads, text in [
("cp", flexible_cps, "Flexible charging parks"),
("hp", flexible_hps, "Flexible heatpumps"),
("dsm", flexible_loads, "Flexible loads"),
("storage", flexible_storage_units, "Storage units"),
]:
if (flex not in opf_flex) & (len(loads) != 0):
logger.info("{} will be optimized.".format(text))
opf_flex.append(flex)
hv_flex_dict = dict()
# Sorts buses such that bus0 is always the upstream bus
edisgo_object.topology.sort_buses()
# Calculate line costs
costs = line_expansion_costs(edisgo_object).drop(columns="voltage_level")
# convert eDisGo object to pypsa network structure
psa_net = edisgo_object.to_pypsa()
# add line costs to psa_net
psa_net.lines = psa_net.lines.merge(costs, left_index=True, right_index=True)
psa_net.lines.capital_cost = (
psa_net.lines.costs_earthworks + psa_net.lines.costs_cable
)
# aggregate parallel transformers
aggregate_parallel_transformers(psa_net)
psa_net.transformers.capital_cost = edisgo_object.config._data[
"costs_transformers"
]["lv"]
# calculate per unit values
pypsa.pf.calculate_dependent_values(psa_net)
# build PowerModels structure
pm = _init_pm()
timesteps = len(psa_net.snapshots) # number of considered timesteps
pm["name"] = "ding0_{}_t_{}".format(edisgo_object.topology.id, timesteps)
pm["time_elapsed"] = int(
(psa_net.snapshots[1] - psa_net.snapshots[0]).seconds / 3600
) # length of timesteps in hours
pm["baseMVA"] = s_base
pm["source_version"] = 2
pm["flexibilities"] = opf_flex
logger.info("Transforming busses into PowerModels dictionary format.")
_build_bus(psa_net, edisgo_object, pm, flexible_storage_units)
logger.info("Transforming generators into PowerModels dictionary format.")
_build_gen(edisgo_object, psa_net, pm, flexible_storage_units, s_base)
logger.info(
"Transforming lines and transformers into PowerModels dictionary format."
)
_build_branch(edisgo_object, psa_net, pm, flexible_storage_units, s_base)
if len(flexible_storage_units) > 0:
logger.info("Transforming storage units into PowerModels dictionary format.")
_build_battery_storage(
edisgo_object, psa_net, pm, flexible_storage_units, s_base, opf_version
)
if len(flexible_cps) > 0:
logger.info("Transforming charging points into PowerModels dictionary format.")
flexible_cps = _build_electromobility(
edisgo_object,
psa_net,
pm,
s_base,
flexible_cps,
)
if len(flexible_hps) > 0:
logger.info("Transforming heatpumps into PowerModels dictionary format.")
_build_heatpump(psa_net, pm, edisgo_object, s_base, flexible_hps)
logger.info(
"Transforming heat storage units into PowerModels dictionary format."
)
_build_heat_storage(
psa_net, pm, edisgo_object, s_base, flexible_hps, opf_version
)
if len(flexible_loads) > 0:
logger.info("Transforming DSM loads into PowerModels dictionary format.")
flexible_loads = _build_dsm(edisgo_object, psa_net, pm, s_base, flexible_loads)
if len(psa_net.loads) > 0:
logger.info("Transforming loads into PowerModels dictionary format.")
_build_load(
edisgo_object,
psa_net,
pm,
s_base,
flexible_cps,
flexible_hps,
flexible_storage_units,
)
else:
logger.warning("No loads found in network.")
if (opf_version == 3) | (opf_version == 4):
if edisgo_object.overlying_grid.heat_pump_central_active_power.isna()[0]:
edisgo_object.overlying_grid.heat_pump_central_active_power[:] = 0
hv_flex_dict = {
"curt": edisgo_object.overlying_grid.renewables_curtailment.round(20)
/ s_base,
"storage": edisgo_object.overlying_grid.storage_units_active_power.round(20)
/ s_base,
"cp": edisgo_object.overlying_grid.electromobility_active_power.round(20)
/ s_base,
"hp": (
edisgo_object.overlying_grid.heat_pump_decentral_active_power.round(20)
+ edisgo_object.overlying_grid.heat_pump_central_active_power.round(20)
)
/ s_base,
"dsm": edisgo_object.overlying_grid.dsm_active_power.round(20) / s_base,
}
try:
logger.info(
"Transforming overlying grid requirements into PowerModels dictionary "
"format."
)
_build_hv_requirements(
psa_net,
edisgo_object,
pm,
s_base,
opf_flex,
flexible_cps,
flexible_hps,
flexible_storage_units,
flexible_loads,
hv_flex_dict,
)
except IndexError:
logger.warning(
"Overlying grid component of eDisGo object has no entries."
" Changing optimization version to '2' (without high voltage"
" requirements)."
)
opf_version = 2
pm["opf_version"] = opf_version
logger.info(
"Transforming components timeseries into PowerModels dictionary format."
)
_build_timeseries(
psa_net,
pm,
edisgo_object,
s_base,
flexible_cps,
flexible_hps,
flexible_loads,
flexible_storage_units,
opf_flex,
hv_flex_dict,
)
return pm, hv_flex_dict
[docs]
def from_powermodels(
edisgo_object,
pm_results,
hv_flex_dict,
s_base=1,
):
"""
Convert results from optimization in PowerModels network data format to eDisGo data
format and updates timeseries values of flexibilities on eDisGo object.
Parameters
----------
edisgo_object : :class:`~.EDisGo`
pm_results : dict or str
Dictionary or path to json file that contains all optimization results in
PowerModels network data format.
hv_flex_dict : dict
Dictionary containing time series of HV requirement for each flexibility
retrieved from overlying grid component of edisgo object.
s_base : int
Base value of apparent power for per unit system.
Default: 1 MVA.
"""
if type(pm_results) == str:
with open(pm_results) as f:
pm = json.loads(json.load(f))
elif type(pm_results) == dict:
pm = pm_results
else:
raise ValueError(
"Parameter 'pm_results' must be either dictionary or path to json file."
)
try:
edisgo_object.opf_results.solution_time = pm["solve_time"]
except KeyError:
raise exceptions.InfeasibleModelError("Julia process failed!")
edisgo_object.opf_results.status = pm["status"]
edisgo_object.opf_results.solver = pm["solver"]
flex_dicts = {
"curt": ["gen_nd", "pgc"],
"hp": ["heatpumps", "php"],
"cp": ["electromobility", "pcp"],
"storage": ["storage", "pf"],
"dsm": ["dsm", "pdsm"],
}
timesteps = pd.Series([int(k) for k in pm["nw"].keys()]).sort_values().values
logger.info("Writing OPF results to eDisGo object.")
# write active power OPF results to edisgo object
for flexibility in pm_results["nw"]["1"]["flexibilities"]:
flex, variable = flex_dicts[flexibility]
names = [
pm["nw"]["1"][flex][flex_comp]["name"]
for flex_comp in list(pm["nw"]["1"][flex].keys())
]
# replace storage power values by branch power values of virtual branch to
# account for losses
if flex == "storage":
branches = [
pm["nw"]["1"][flex][flex_comp]["virtual_branch"]
for flex_comp in list(pm["nw"]["1"][flex].keys())
]
data = [
[
-pm["nw"][str(t)]["branch"][branch][variable] * s_base
for branch in branches
]
for t in timesteps
]
else:
data = [
[
pm["nw"][str(t)][flex][flex_comp][variable] * s_base
for flex_comp in list(pm["nw"]["1"][flex].keys())
]
for t in timesteps
]
results = pd.DataFrame(index=timesteps, columns=names, data=data)
if (flex == "gen_nd") & (pm["nw"]["1"]["opf_version"] in [3, 4]):
edisgo_object.timeseries._generators_active_power.loc[:, names] = (
edisgo_object.timeseries.generators_active_power.loc[:, names].values
- results[names].values
)
elif flex in ["heatpumps", "electromobility"]:
edisgo_object.timeseries._loads_active_power.loc[:, names] = results[
names
].values
elif flex == "dsm":
edisgo_object.timeseries._loads_active_power.loc[:, names] = (
edisgo_object.timeseries._loads_active_power.loc[:, names].values
+ results[names].values
)
elif flex == "storage":
try:
if edisgo_object.timeseries.storage_units_active_power.empty:
edisgo_object.timeseries.storage_units_active_power = pd.DataFrame(
index=edisgo_object.timeseries.timeindex,
columns=names,
data=results[names].values,
)
else:
edisgo_object.timeseries._storage_units_active_power.loc[
:, names
] = results[names].values
except AttributeError:
setattr(
edisgo_object.timeseries,
"storage_units_active_power",
pd.DataFrame(
index=edisgo_object.timeseries.timeindex,
columns=names,
data=results[names].values,
),
)
# calculate corresponding reactive power values
edisgo_object.set_time_series_reactive_power_control()
# Check values of slack variables for HV requirement constraint
if pm["nw"]["1"]["opf_version"] in [3, 4]:
df = _result_df(
pm,
"HV_requirements",
"phvs",
timesteps,
edisgo_object.timeseries.timeindex,
s_base,
)
# save HV slack results to edisgo object
edisgo_object.opf_results.hv_requirement_slacks_t = df
# calculate relative error
df2 = deepcopy(df)
for flex in df2.columns:
abs_error = abs(df2[flex].values - hv_flex_dict[flex])
rel_error = [
abs_error[i] / hv_flex_dict[flex][i]
if ((abs_error > 0.01)[i] & (hv_flex_dict[flex][i] != 0))
else 0
for i in range(len(abs_error))
]
df2[flex] = rel_error
# write results to edisgo object
edisgo_object.opf_results.overlying_grid = pd.DataFrame(
columns=[
"Highest relative error",
"Mean relative error",
"Sum relative error",
],
index=df2.columns,
data=np.asarray(
[df2.max().values, (df2.sum() / len(df2)).values, df2.sum().values]
).transpose(),
)
for flex in df2.columns:
if (
edisgo_object.opf_results.overlying_grid["Highest relative error"][flex]
> 0.05
).any():
logger.warning(
"Highest relative error of {} variable exceeds 5%.".format(flex)
)
# save slack generator variable to edisgo object
df = pd.DataFrame(index=edisgo_object.timeseries.timeindex, columns=["pg", "qg"])
for gen in list(pm["nw"]["1"]["gen_slack"].keys()):
df["pg"] = [
pm["nw"][str(t)]["gen_slack"][gen]["pgs"] * s_base for t in timesteps
]
df["qg"] = [
pm["nw"][str(t)]["gen_slack"][gen]["qgs"] * s_base for t in timesteps
]
edisgo_object.opf_results.slack_generator_t = df
# save internal battery storage variable to edisgo object
df = _result_df(
pm,
"storage",
"ps",
timesteps,
edisgo_object.timeseries.timeindex,
s_base,
)
edisgo_object.opf_results.battery_storage_t.p = df
df = _result_df(
pm,
"storage",
"se",
timesteps,
edisgo_object.timeseries.timeindex,
s_base,
)
edisgo_object.opf_results.battery_storage_t.e = df
# save heat storage variables to edisgo object
df = _result_df(
pm,
"heat_storage",
"phs",
timesteps,
edisgo_object.timeseries.timeindex,
s_base,
)
edisgo_object.opf_results.heat_storage_t.p = df
df = _result_df(
pm,
"heat_storage",
"hse",
timesteps,
edisgo_object.timeseries.timeindex,
s_base,
)
edisgo_object.opf_results.heat_storage_t.e = df
df = _result_df(
pm,
"heat_storage",
"phss",
timesteps,
edisgo_object.timeseries.timeindex,
s_base,
)
edisgo_object.opf_results.heat_storage_t.p_slack = df
if pm["nw"]["1"]["opf_version"] in [2, 4]:
slacks = [
("gen", "pgens"),
("gen_nd", "pgc"),
("load", "pds"),
("electromobility", "pcps"),
("heatpumps", "phps"),
("heatpumps", "phps2"),
]
for comp, var in slacks:
# save slacks to edisgo object
df = _result_df(
pm, comp, var, timesteps, edisgo_object.timeseries.timeindex, s_base
)
if comp == "gen":
edisgo_object.opf_results.grid_slacks_t.gen_d_crt = df
elif comp == "gen_nd":
edisgo_object.opf_results.grid_slacks_t.gen_nd_crt = df
elif comp == "load":
edisgo_object.opf_results.grid_slacks_t.load_shedding = df
elif comp == "electromobility":
edisgo_object.opf_results.grid_slacks_t.cp_load_shedding = df
elif comp == "heatpumps":
if var == "phps":
edisgo_object.opf_results.grid_slacks_t.hp_load_shedding = df
elif var == "phps2":
edisgo_object.opf_results.grid_slacks_t.hp_operation_slack = df
# save line flows and currents to edisgo object
for variable in ["pf", "qf", "ccm"]:
df = _result_df(
pm,
"branch",
variable,
timesteps,
edisgo_object.timeseries.timeindex,
s_base,
)
if variable == "pf":
edisgo_object.opf_results.lines_t.p = df
elif variable == "qf":
edisgo_object.opf_results.lines_t.q = df
elif variable == "ccm":
edisgo_object.opf_results.lines_t.ccm = df
def _init_pm():
"""
Initialize empty PowerModels dictionary.
Returns
-------
dict
Dictionary that contains all network data in PowerModels network data
format.
"""
pm = {
"gen": dict(),
"gen_nd": dict(),
"gen_slack": dict(),
"branch": dict(),
"bus": dict(),
"dcline": dict(),
"load": dict(),
"storage": dict(),
"switch": dict(),
"electromobility": dict(),
"heatpumps": dict(),
"heat_storage": dict(),
"dsm": dict(),
"HV_requirements": dict(),
"baseMVA": 1,
"source_version": 2,
"shunt": dict(),
"sourcetype": "eDisGo",
"per_unit": True,
"name": "name",
"time_series": {
"gen": dict(),
"load": dict(),
"storage": dict(),
"electromobility": dict(),
"heatpumps": dict(),
"dsm": dict(),
"HV_requirements": dict(),
"num_steps": int,
},
}
return pm
def _build_bus(psa_net, edisgo_obj, pm, flexible_storage_units):
"""
Build bus dictionary in PowerModels network data format and add it to
PowerModels dictionary 'pm'.
Parameters
----------
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
edisgo_obj : :class:`~.EDisGo`
pm : dict
(PowerModels) dictionary.
flexible_storage_units : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible storage units.
"""
bus_types = ["PQ", "PV", "Slack", "None"]
bus_types_int = np.array(
[bus_types.index(b_type) + 1 for b_type in psa_net.buses["control"].values],
dtype=int,
)
grid_level = {20: "mv", 10: "mv", 0.4: "lv"}
v_max = [min(val, 1.1) for val in psa_net.buses["v_mag_pu_max"].values]
v_min = [max(val, 0.9) for val in psa_net.buses["v_mag_pu_min"].values]
for bus_i in np.arange(len(psa_net.buses.index)):
pm["bus"][str(bus_i + 1)] = {
"index": bus_i + 1,
"bus_i": bus_i + 1,
"zone": 1,
"bus_type": bus_types_int[bus_i],
"vmax": v_max[bus_i],
"vmin": v_min[bus_i],
"va": 0,
"vm": 1,
"storage": False,
"name": psa_net.buses.index[bus_i],
"base_kv": psa_net.buses.v_nom[bus_i],
"grid_level": grid_level[psa_net.buses.v_nom[bus_i]],
}
# add virtual busses for storage units
for stor_i in np.arange(len(flexible_storage_units)):
idx_bus = _mapping(
psa_net,
edisgo_obj,
psa_net.storage_units.bus.loc[flexible_storage_units[stor_i]],
flexible_storage_units=flexible_storage_units,
)
pm["bus"][str(stor_i + len(psa_net.buses.index) + 1)] = {
"index": stor_i + len(psa_net.buses.index) + 1,
"bus_i": stor_i + len(psa_net.buses.index) + 1,
"zone": 1,
"bus_type": bus_types_int[idx_bus - 1],
"vmax": v_max[idx_bus - 1],
"vmin": v_min[idx_bus - 1],
"va": 0,
"vm": 1,
"storage": True,
"name": psa_net.buses.index[idx_bus - 1] + "_bss",
"base_kv": psa_net.buses.v_nom[idx_bus - 1],
"grid_level": grid_level[psa_net.buses.v_nom[idx_bus - 1]],
}
def _build_gen(edisgo_obj, psa_net, pm, flexible_storage_units, s_base):
"""
Build slack, dispatchable and non-dispatchable generator dictionaries in PowerModels
network data format and add them to PowerModels dictionary 'pm'.
Parameters
----------
edisgo_obj : :class:`~.EDisGo`
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
pm : dict
(PowerModels) dictionary.
s_base : int
Base value of apparent power for per unit system.
flexible_storage_units : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible storage units.
"""
# Divide in slack, dispatchable and non-dispatchable generator sets
solar_gens = edisgo_obj.topology.generators_df.index[
edisgo_obj.topology.generators_df.type == "solar"
]
wind_gens = edisgo_obj.topology.generators_df.index[
edisgo_obj.topology.generators_df.type == "wind"
]
disp_gens = edisgo_obj.topology.generators_df.index[
(edisgo_obj.topology.generators_df.type != "wind")
& (edisgo_obj.topology.generators_df.type != "solar")
]
gen_slack = psa_net.generators.loc[psa_net.generators.index == "Generator_slack"]
gen_nondisp = psa_net.generators.loc[
np.concatenate((solar_gens.values, wind_gens.values))
]
gen_disp = psa_net.generators.loc[disp_gens]
# determine slack buses through slack generators
slack_gens_bus = gen_slack.bus.values
for bus in slack_gens_bus:
pm["bus"][
str(
_mapping(
psa_net,
edisgo_obj,
bus,
flexible_storage_units=flexible_storage_units,
)
)
]["bus_type"] = 3
for gen, text in [
(gen_disp, "gen"),
(gen_nondisp, "gen_nd"),
(gen_slack, "gen_slack"),
]:
for gen_i in np.arange(len(gen.index)):
idx_bus = _mapping(
psa_net,
edisgo_obj,
gen.bus[gen_i],
flexible_storage_units=flexible_storage_units,
)
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "gen")
q = [
sign * np.tan(np.arccos(pf)) * gen.p_nom[gen_i],
sign * np.tan(np.arccos(pf)) * gen.p_nom_min[gen_i],
]
pm[text][str(gen_i + 1)] = {
"pg": psa_net.generators_t.p_set[gen.index[gen_i]][0] / s_base,
"qg": psa_net.generators_t.q_set[gen.index[gen_i]][0] / s_base,
"pmax": gen.p_nom[gen_i].round(20) / s_base,
"pmin": gen.p_nom_min[gen_i].round(20) / s_base,
"qmax": max(q).round(20) / s_base,
"qmin": min(q).round(20) / s_base,
"P": 0,
"Q": 0,
"vg": 1,
"pf": pf,
"sign": sign,
"mbase": gen.p_nom[gen_i] / s_base,
"gen_bus": idx_bus,
"gen_status": 1,
"name": gen.index[gen_i],
"index": gen_i + 1,
}
# add active power generation of inflexible storage units to gen dict
inflexible_storage_units = [
storage
for storage in psa_net.storage_units.index
if storage not in flexible_storage_units
]
if len(inflexible_storage_units) > 0:
for stor_i in np.arange(len(inflexible_storage_units)):
idx_bus = _mapping(
psa_net,
edisgo_obj,
psa_net.storage_units.bus.loc[inflexible_storage_units[stor_i]],
flexible_storage_units=flexible_storage_units,
)
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "storage")
p_g = max(
[
psa_net.storage_units_t.p_set[inflexible_storage_units[stor_i]][0],
0.0,
]
)
q_g = min(
[
psa_net.storage_units_t.q_set[inflexible_storage_units[stor_i]][0],
0.0,
]
)
pm["gen"][str(stor_i + len(gen_disp.index) + 1)] = {
"pg": p_g / s_base,
"qg": q_g / s_base,
"pmax": psa_net.storage_units.p_nom.loc[
inflexible_storage_units[stor_i]
].round(20)
/ s_base,
"pmin": -psa_net.storage_units.p_nom.loc[
inflexible_storage_units[stor_i]
].round(20)
/ s_base,
"qmax": np.tan(np.arccos(pf))
* psa_net.storage_units.p_nom.loc[
inflexible_storage_units[stor_i]
].round(20)
/ s_base,
"qmin": -np.tan(np.arccos(pf))
* psa_net.storage_units.p_nom.loc[
inflexible_storage_units[stor_i]
].round(20)
/ s_base,
"P": 0,
"Q": 0,
"vg": 1,
"pf": pf,
"sign": sign,
"mbase": psa_net.storage_units.p_nom.loc[
inflexible_storage_units[stor_i]
].round(20)
/ s_base,
"gen_bus": idx_bus,
"gen_status": 1,
"name": inflexible_storage_units[stor_i],
"index": stor_i + len(gen_disp.index) + 1,
}
def _build_branch(edisgo_obj, psa_net, pm, flexible_storage_units, s_base):
"""
Build branch dictionary in PowerModels network data format and add it to
PowerModels dictionary 'pm'.
Parameters
----------
edisgo_obj : :class:`~.EDisGo`
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
pm : dict
(PowerModels) dictionary.
flexible_storage_units : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible storage units.
s_base : int
Base value of apparent power for per unit system.
"""
branches = pd.concat([psa_net.lines, psa_net.transformers])
transformer = ~branches.tap_ratio.isna()
tap = branches.tap_ratio.fillna(1)
shift = branches.phase_shift.fillna(0)
for par, val, quant, text, unit in [
("r_pu", branches.r_pu, 0.002, "resistance", "p.u."),
("x_pu", branches.x_pu, 0.002, "reactance", "p.u."),
]:
min_value = min(val.loc[val > val.quantile(quant)])
if math.floor(math.log10(val.min())) <= -4:
# only modify r, x and l values if min value is too small
branches[par] = val.clip(lower=min_value)
logger.warning(
"Min value of {} is too small. Lowest {}% of {} values will be set "
"to {} {}".format(text, 100 * quant, text, min_value, unit)
)
for branch_i in np.arange(len(branches.index)):
idx_f_bus = _mapping(
psa_net,
edisgo_obj,
branches.bus0[branch_i],
flexible_storage_units=flexible_storage_units,
)
idx_t_bus = _mapping(
psa_net,
edisgo_obj,
branches.bus1[branch_i],
flexible_storage_units=flexible_storage_units,
)
pm["branch"][str(branch_i + 1)] = {
"name": branches.index[branch_i],
"br_r": branches.r_pu[branch_i] * s_base,
"r": branches.r[branch_i],
"br_x": branches.x_pu[branch_i] * s_base,
"f_bus": idx_f_bus,
"t_bus": idx_t_bus,
"g_to": branches.g_pu[branch_i] / 2 * s_base,
"g_fr": branches.g_pu[branch_i] / 2 * s_base,
"b_to": branches.b_pu[branch_i] / 2 * s_base,
"b_fr": branches.b_pu[branch_i] / 2 * s_base,
"shift": shift[branch_i],
"br_status": 1.0,
"rate_a": branches.s_nom[branch_i].real / s_base,
"rate_b": 250 / s_base,
"rate_c": 250 / s_base,
"angmin": -np.pi / 6,
"angmax": np.pi / 6,
"transformer": bool(transformer[branch_i]),
"storage": False,
"tap": tap[branch_i],
"length": branches.length.fillna(1)[branch_i].round(20),
"cost": branches.capital_cost[branch_i].round(20),
"storage_pf": 0,
"index": branch_i + 1,
}
# add virtual branch for storage units
for stor_i in np.arange(len(flexible_storage_units)):
idx_bus = _mapping(
psa_net,
edisgo_obj,
psa_net.storage_units.bus.loc[flexible_storage_units[stor_i]],
flexible_storage_units=flexible_storage_units,
)
# retrieve power factor from config
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "storage")
pm["branch"][str(stor_i + len(branches.index) + 1)] = {
"name": "bss_branch_" + str(stor_i + 1),
"br_r": (0.017 * s_base / (psa_net.buses.v_nom[idx_bus - 1] ** 2)).round(
10
),
"r": 0.017,
"br_x": 0,
"f_bus": idx_bus,
"t_bus": stor_i + len(psa_net.buses.index) + 1,
"g_to": 0,
"g_fr": 0,
"b_to": 0,
"b_fr": 0,
"shift": 0,
"br_status": 1.0,
"rate_a": psa_net.storage_units.p_nom.loc[
flexible_storage_units[stor_i]
].round(20)
/ s_base,
"rate_b": 250 / s_base,
"rate_c": 250 / s_base,
"angmin": -np.pi / 6,
"angmax": np.pi / 6,
"transformer": False,
"storage": True,
"tap": 1,
"length": 1,
"cost": 0,
"cost_inverse": 0,
"storage_pf": np.tan(np.arccos(pf)) * sign,
"index": stor_i + len(branches.index) + 1,
}
def _build_load(
edisgo_obj, psa_net, pm, s_base, flexible_cps, flexible_hps, flexible_storage_units
):
"""
Build load dictionary in PowerModels network data format and add it to
PowerModels dictionary 'pm'.
Parameters
----------
edisgo_obj : :class:`~.EDisGo`
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
pm : dict
(PowerModels) dictionary.
s_base : int
Base value of apparent power for per unit system.
flexible_cps : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all charging points that allow for flexible charging.
flexible_hps : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all heat pumps that allow for flexible operation due to an
attached heat storage.
flexible_storage_units : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible storage units.
"""
flex_loads = np.concatenate((flexible_hps, flexible_cps))
inflexible_storage_units = [
storage
for storage in psa_net.storage_units.index
if storage not in flexible_storage_units
]
if len(flex_loads) == 0:
loads_df = psa_net.loads
else:
loads_df = psa_net.loads.drop(flex_loads)
for load_i in np.arange(len(loads_df.index)):
idx_bus = _mapping(
psa_net,
edisgo_obj,
loads_df.bus[load_i],
flexible_storage_units=flexible_storage_units,
)
if (
edisgo_obj.topology.loads_df.loc[loads_df.index[load_i]].type
== "conventional_load"
):
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "load")
elif (
edisgo_obj.topology.loads_df.loc[loads_df.index[load_i]].type == "heat_pump"
):
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "hp")
elif (
edisgo_obj.topology.loads_df.loc[loads_df.index[load_i]].type
== "charging_point"
):
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "cp")
else:
logger.warning(
"No type specified for load {}. Power factor and sign will"
"be set for conventional load.".format(loads_df.index[load_i])
)
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "load")
p_d = psa_net.loads_t.p_set[loads_df.index[load_i]]
q_d = psa_net.loads_t.q_set[loads_df.index[load_i]]
pm["load"][str(load_i + 1)] = {
"pd": p_d[0].round(20) / s_base,
"qd": q_d[0].round(20) / s_base,
"load_bus": idx_bus,
"status": True,
"pf": pf,
"sign": sign,
"name": loads_df.index[load_i],
"index": load_i + 1,
}
if len(inflexible_storage_units) > 0:
for stor_i in np.arange(len(inflexible_storage_units)):
idx_bus = _mapping(
psa_net,
edisgo_obj,
psa_net.storage_units.bus.loc[inflexible_storage_units[stor_i]],
flexible_storage_units=flexible_storage_units,
)
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "storage")
p_d = -min(
[
psa_net.storage_units_t.p_set[inflexible_storage_units[stor_i]][0],
np.float64(0.0),
]
)
q_d = -max(
[
psa_net.storage_units_t.q_set[inflexible_storage_units[stor_i]][0],
np.float64(0.0),
]
)
pm["load"][str(stor_i + len(loads_df.index) + 1)] = {
"pd": p_d.round(20) / s_base,
"qd": q_d.round(20) / s_base,
"load_bus": idx_bus,
"status": True,
"pf": pf,
"sign": sign,
"name": inflexible_storage_units[stor_i],
"index": stor_i + len(loads_df.index) + 1,
}
def _build_battery_storage(
edisgo_obj, psa_net, pm, flexible_storage_units, s_base, opf_version
):
"""
Build battery storage dictionary in PowerModels network data format and add
it to PowerModels dictionary 'pm'.
Parameters
----------
edisgo_obj : :class:`~.EDisGo`
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
pm : dict
(PowerModels) dictionary.
flexible_storage_units : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible storage units.
s_base : int
Base value of apparent power for per unit system.
opf_version : int
Version of optimization models to choose from. Must be one of [1, 2, 3, 4].
For more information see :func:`edisgo.opf.powermodels_opf.pm_optimize`.
"""
branches = pd.concat([psa_net.lines, psa_net.transformers])
if not edisgo_obj.overlying_grid.storage_units_soc.empty:
data = pd.concat(
[edisgo_obj.overlying_grid.storage_units_soc]
* len(edisgo_obj.topology.storage_units_df),
axis=1,
).values
else:
data = 0
# ToDo: find better place to save soc data to
edisgo_obj.overlying_grid.storage_units_soc = (
pd.DataFrame(
columns=flexible_storage_units,
data=data,
index=edisgo_obj.timeseries.timeindex.union(
[
edisgo_obj.timeseries.timeindex[-1]
+ edisgo_obj.timeseries.timeindex.freq
]
),
)
* edisgo_obj.topology.storage_units_df.p_nom
* edisgo_obj.topology.storage_units_df.max_hours
)
for stor_i in np.arange(len(flexible_storage_units)):
idx_bus = _mapping(
psa_net,
edisgo_obj,
psa_net.storage_units.bus.loc[flexible_storage_units[stor_i]],
flexible_storage_units=flexible_storage_units,
)
# retrieve power factor from config
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "storage")
e_max = (
psa_net.storage_units.p_nom.loc[flexible_storage_units[stor_i]]
* psa_net.storage_units.max_hours.loc[flexible_storage_units[stor_i]]
)
pm["storage"][str(stor_i + 1)] = {
"r": 0,
"x": 0,
"p_loss": 0,
"q_loss": 0,
"pf": pf,
"sign": sign,
"virtual_branch": str(stor_i + len(branches.index) + 1),
"ps": psa_net.storage_units.p_set[flexible_storage_units[stor_i]].round(20)
/ s_base,
"qs": psa_net.storage_units.q_set[flexible_storage_units[stor_i]].round(20)
/ s_base,
"pmax": psa_net.storage_units.p_nom.loc[
flexible_storage_units[stor_i]
].round(20)
/ s_base,
"pmin": -psa_net.storage_units.p_nom.loc[
flexible_storage_units[stor_i]
].round(20)
/ s_base,
"qmax": np.tan(np.arccos(pf))
* psa_net.storage_units.p_nom.loc[flexible_storage_units[stor_i]].round(20)
/ s_base,
"qmin": -np.tan(np.arccos(pf))
* psa_net.storage_units.p_nom.loc[flexible_storage_units[stor_i]].round(20)
/ s_base,
"energy": (
psa_net.storage_units.state_of_charge_initial.loc[
flexible_storage_units[stor_i]
]
* e_max
).round(20)
/ s_base,
"soc_initial": (
edisgo_obj.overlying_grid.storage_units_soc[
flexible_storage_units[stor_i]
]
.iloc[0]
.round(20)
),
"soc_end": edisgo_obj.overlying_grid.storage_units_soc[
flexible_storage_units[stor_i]
]
.iloc[-1]
.round(20),
"energy_rating": e_max.round(20) / s_base,
"thermal_rating": 1000,
"charge_rating": psa_net.storage_units.p_nom.loc[
flexible_storage_units[stor_i]
].round(20)
/ s_base,
"discharge_rating": psa_net.storage_units.p_nom.loc[
flexible_storage_units[stor_i]
].round(20)
/ s_base,
"charge_efficiency": 0.9,
"discharge_efficiency": 0.9,
"storage_bus": stor_i + len(psa_net.buses.index) + 1,
"name": flexible_storage_units[stor_i],
"status": True,
"index": stor_i + 1,
}
def _build_electromobility(edisgo_obj, psa_net, pm, s_base, flexible_cps):
"""
Build electromobility dictionary and add it to PowerModels dictionary 'pm'.
Parameters
----------
edisgo_obj : :class:`~.EDisGo`
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
pm : dict
(PowerModels) dictionary.
s_base : int
Base value of apparent power for per unit system.
flexible_cps : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all charging points that allow for flexible charging.
Returns
----------
flexible_cps : :numpy:`numpy.ndarray<ndarray>` or list
Updated array containing all charging points that allow for flexible charging.
"""
flex_bands_df = edisgo_obj.electromobility.flexibility_bands
if (flex_bands_df["lower_energy"] > flex_bands_df["upper_energy"]).any().any():
logger.warning(
"Upper energy level is smaller than lower energy level for "
"charging parks {}! Charging Parks will be changed into inflexible "
"loads.".format(
flexible_cps[
(
flex_bands_df["lower_energy"] > flex_bands_df["upper_energy"]
).any()[0]
]
)
)
flexible_cps = flexible_cps[
~(flex_bands_df["lower_energy"] > flex_bands_df["upper_energy"]).any()
]
emob_df = psa_net.loads.loc[flexible_cps]
for cp_i in np.arange(len(emob_df.index)):
idx_bus = _mapping(psa_net, edisgo_obj, emob_df.bus[cp_i])
# retrieve power factor and sign from config
try:
eta = edisgo_obj.electromobility.simbev_config_df.eta_cp.values[0]
except IndexError:
eta = 0.9
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "cp")
q = (
sign
* np.tan(np.arccos(pf))
* flex_bands_df["upper_power"][emob_df.index[cp_i]][0]
)
p_max = flex_bands_df["upper_power"][emob_df.index[cp_i]]
e_min = flex_bands_df["lower_energy"][emob_df.index[cp_i]]
e_max = flex_bands_df["upper_energy"][emob_df.index[cp_i]]
try:
soc_initial = edisgo_obj.electromobility.initial_soc_df[emob_df.index[cp_i]]
except AttributeError:
soc_initial = 1 / 2 * (e_min[0] + e_max[0])
pm["electromobility"][str(cp_i + 1)] = {
"pd": 0,
"qd": 0,
"pf": pf,
"sign": sign,
"p_min": 0,
"p_max": p_max[0].round(20) / s_base,
"q_min": min(q, 0).round(20) / s_base,
"q_max": max(q, 0).round(20) / s_base,
"e_min": e_min[0].round(20) / s_base,
"e_max": e_max[0].round(20) / s_base,
"energy": soc_initial.round(20),
"eta": eta,
"cp_bus": idx_bus,
"name": emob_df.index[cp_i],
"index": cp_i + 1,
}
return flexible_cps
def _build_heatpump(psa_net, pm, edisgo_obj, s_base, flexible_hps):
"""
Build heat pump dictionary and add it to PowerModels dictionary 'pm'.
Parameters
----------
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
pm : dict
(PowerModels) dictionary.
edisgo_obj : :class:`~.EDisGo`
s_base : int
Base value of apparent power for per unit system.
flexible_hps : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all heat pumps that allow for flexible operation due to an
attached heat storage.
"""
heat_df = psa_net.loads.loc[flexible_hps] # electric load
heat_df2 = edisgo_obj.heat_pump.heat_demand_df[flexible_hps] # thermal load
hp_cop = edisgo_obj.heat_pump.cop_df[flexible_hps]
hp_p_nom = edisgo_obj.topology.loads_df.p_set[flexible_hps]
comparison = (heat_df2[hp_p_nom.index] > hp_cop * hp_p_nom.squeeze()).any()
if comparison.any():
logger.warning(
"Heat demand is higher than rated heatpump power"
" of heatpumps: {}. Demand can not be covered if no sufficient"
" heat storage capacities are available.".format(
comparison.index[comparison.values].values
)
)
for hp_i in np.arange(len(heat_df.index)):
idx_bus = _mapping(psa_net, edisgo_obj, heat_df.bus[hp_i])
# retrieve power factor and sign from config
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "hp")
q = sign * np.tan(np.arccos(pf)) * heat_df.p_set[hp_i]
p_d = heat_df2[heat_df.index[hp_i]]
pm["heatpumps"][str(hp_i + 1)] = {
"pd": p_d[0].round(20) / s_base, # heat demand
"pf": pf,
"sign": sign,
"p_min": 0,
"p_max": heat_df.p_set[hp_i].round(20) / s_base,
"q_min": min(q, 0).round(20) / s_base,
"q_max": max(q, 0).round(20) / s_base,
"cop": hp_cop[heat_df.index[hp_i]][0].round(20),
"hp_bus": idx_bus,
"name": heat_df.index[hp_i],
"index": hp_i + 1,
}
def _build_heat_storage(psa_net, pm, edisgo_obj, s_base, flexible_hps, opf_version):
"""
Build heat storage dictionary and add it to PowerModels dictionary 'pm'.
Parameters
----------
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
pm : dict
(PowerModels) dictionary.
edisgo_obj : :class:`~.EDisGo`
s_base : int
Base value of apparent power for per unit system.
flexible_hps : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all heat pumps that allow for flexible operation due to an
attached heat storage.
opf_version : int
Version of optimization models to choose from. Must be one of [1, 2, 3, 4].
For more information see :func:`edisgo.opf.powermodels_opf.pm_optimize`.
"""
# add TES with 0 capacity for every flexible hp without TES
hp_no_tes = np.setdiff1d(
flexible_hps, edisgo_obj.heat_pump.thermal_storage_units_df.index.values
)
df = pd.DataFrame(index=hp_no_tes, columns=["efficiency", "capacity"], data=0.0)
heat_storage_df = pd.concat([edisgo_obj.heat_pump.thermal_storage_units_df, df])
decentral_hps = np.intersect1d(
edisgo_obj.topology.loads_df.loc[
edisgo_obj.topology.loads_df.sector == "individual_heating"
].index,
flexible_hps,
)
if not edisgo_obj.overlying_grid.thermal_storage_units_decentral_soc.empty:
data = pd.concat(
[edisgo_obj.overlying_grid.thermal_storage_units_decentral_soc]
* len(decentral_hps),
axis=1,
).values
else:
data = 0.0
df_decentral = (
pd.DataFrame(
columns=decentral_hps,
data=data,
index=edisgo_obj.timeseries.timeindex.union(
[
edisgo_obj.timeseries.timeindex[-1]
+ edisgo_obj.timeseries.timeindex.freq
]
),
)
* heat_storage_df.loc[decentral_hps].capacity
)
central_hps = np.intersect1d(
edisgo_obj.topology.loads_df.loc[
(edisgo_obj.topology.loads_df.type == "heat_pump")
& (edisgo_obj.topology.loads_df.sector != "individual_heating")
].index,
flexible_hps,
)
if not edisgo_obj.overlying_grid.thermal_storage_units_central_soc.empty:
data = edisgo_obj.overlying_grid.thermal_storage_units_central_soc[
edisgo_obj.topology.loads_df.loc[central_hps]
.district_heating_id.astype(int)
.astype(str)
].values
else:
data = 0.0
df_central = (
pd.DataFrame(
columns=central_hps,
data=data,
index=edisgo_obj.timeseries.timeindex.union(
[
edisgo_obj.timeseries.timeindex[-1]
+ edisgo_obj.timeseries.timeindex.freq
]
),
)
* heat_storage_df.loc[central_hps].capacity
)
edisgo_obj.overlying_grid.heat_storage_units_soc = pd.concat(
[df_decentral, df_central], axis=1
)
heat_storage_df = heat_storage_df.loc[flexible_hps]
for stor_i in np.arange(len(flexible_hps)):
idx_bus = _mapping(
psa_net, edisgo_obj, psa_net.loads.loc[flexible_hps].bus[stor_i]
)
if (
edisgo_obj.topology.loads_df.loc[heat_storage_df.index[stor_i]].sector
!= "individual_heating"
):
p_loss = 0
else:
p_loss = 0.04
pm["heat_storage"][str(stor_i + 1)] = {
"ps": 0,
"p_loss": p_loss, # 4% of SOC per day
"energy": 0,
"capacity": heat_storage_df.capacity[stor_i].round(20) / s_base,
"charge_efficiency": heat_storage_df.efficiency[stor_i].round(20),
"discharge_efficiency": heat_storage_df.efficiency[stor_i].round(20),
"storage_bus": idx_bus,
"name": heat_storage_df.index[stor_i],
"soc_initial": (
edisgo_obj.overlying_grid.heat_storage_units_soc[
heat_storage_df.index[stor_i]
]
.iloc[0]
.round(20)
),
"soc_end": edisgo_obj.overlying_grid.heat_storage_units_soc[
heat_storage_df.index[stor_i]
]
.iloc[-1]
.round(20),
"status": True,
"index": stor_i + 1,
}
def _build_dsm(edisgo_obj, psa_net, pm, s_base, flexible_loads):
"""
Build dsm 'storage' dictionary and add it to PowerModels dictionary 'pm'.
Parameters
----------
edisgo_obj : :class:`~.EDisGo`
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
pm : dict
(PowerModels) dictionary.
s_base : int
Base value of apparent power for per unit system.
flexible_loads : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all flexible loads that allow for application of demand side
management strategy.
Returns
----------
:numpy:`numpy.ndarray<ndarray>` or list
Updated array containing all flexible loads that allow for application of demand
side management strategy.
"""
if (
len(
flexible_loads[
(
edisgo_obj.dsm.p_min[flexible_loads]
> edisgo_obj.dsm.p_max[flexible_loads]
)
.any()
.values
]
)
> 0
):
logger.warning(
"Upper power level is smaller than lower power level for "
"DSM loads {}! DSM loads will be changed into inflexible loads.".format(
flexible_loads[
(
edisgo_obj.dsm.p_min[flexible_loads]
> edisgo_obj.dsm.p_max[flexible_loads]
).any()
]
)
)
flexible_loads = flexible_loads[
~(
edisgo_obj.dsm.p_min[flexible_loads]
> edisgo_obj.dsm.p_max[flexible_loads]
).any()
]
if (
len(
flexible_loads[
(
edisgo_obj.dsm.e_min[flexible_loads]
> edisgo_obj.dsm.e_max[flexible_loads]
).any()
]
)
> 0
):
logger.warning(
"Upper energy level is smaller than lower energy level for "
"DSM loads {}! DSM loads will be changed into inflexible loads.".format(
flexible_loads[
(
edisgo_obj.dsm.e_min[flexible_loads]
> edisgo_obj.dsm.e_max[flexible_loads]
).any()
]
)
)
flexible_loads = flexible_loads[
~(
edisgo_obj.dsm.e_min[flexible_loads]
> edisgo_obj.dsm.e_max[flexible_loads]
).any()
]
dsm_df = psa_net.loads.loc[flexible_loads]
for dsm_i in np.arange(len(dsm_df.index)):
idx_bus = _mapping(psa_net, edisgo_obj, dsm_df.bus[dsm_i])
# retrieve power factor and sign from config
pf, sign = _get_pf(edisgo_obj, pm, idx_bus, "load")
p_max = edisgo_obj.dsm.p_max[dsm_df.index[dsm_i]]
p_min = edisgo_obj.dsm.p_min[dsm_df.index[dsm_i]]
e_min = edisgo_obj.dsm.e_min[dsm_df.index[dsm_i]]
e_max = edisgo_obj.dsm.e_max[dsm_df.index[dsm_i]]
q = [
sign * np.tan(np.arccos(pf)) * p_max[0],
sign * np.tan(np.arccos(pf)) * p_min[0],
]
pm["dsm"][str(dsm_i + 1)] = {
"pd": 0,
"qd": 0,
"pf": pf,
"sign": sign,
"energy": 0 / s_base,
"p_min": p_min[0].round(20) / s_base,
"p_max": p_max[0].round(20) / s_base,
"q_max": max(q).round(20) / s_base,
"q_min": min(q).round(20) / s_base,
"e_min": e_min[0].round(20) / s_base,
"e_max": e_max[0].round(20) / s_base,
"charge_efficiency": 1,
"discharge_efficiency": 1,
"dsm_bus": idx_bus,
"name": dsm_df.index[dsm_i],
"index": dsm_i + 1,
}
return flexible_loads
def _build_hv_requirements(
psa_net,
edisgo_obj,
pm,
s_base,
opf_flex,
flexible_cps,
flexible_hps,
flexible_storage_units,
flexible_loads,
hv_flex_dict,
):
"""
Build dictionary for HV requirement data in PowerModels network data format and
add it to PowerModels dictionary 'pm'.
Parameters
----------
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
edisgo_obj : :class:`~.EDisGo`
pm : dict
(PowerModels) dictionary.
s_base : int
Base value of apparent power for per unit system.
opf_flex : list
Flexibilities that should be considered in the optimization. Must be any
subset of ["curt", "storage", "cp", "hp", "dsm"]. For more information see
:func:`edisgo.opf.powermodels_opf.pm_optimize`.
flexible_cps : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all charging points that allow for flexible charging.
flexible_hps: :numpy:`numpy.ndarray<ndarray>` or list
Array containing all heat pumps that allow for flexible operation due to an
attached heat storage.
flexible_storage_units : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible storage units.
flexible_loads : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all flexible loads that allow for application of demand side
management strategy.
hv_flex_dict : dict
Dictionary containing time series of HV requirement for each flexibility
retrieved from overlying grid component of edisgo object.
"""
inflexible_cps = [
cp
for cp in edisgo_obj.topology.loads_df.index[
edisgo_obj.topology.loads_df.type == "charging_point"
]
if cp not in flexible_cps
]
inflexible_hps = [
hp
for hp in edisgo_obj.topology.loads_df.index[
edisgo_obj.topology.loads_df.type == "heat_pump"
]
if hp not in flexible_hps
]
inflexible_storage_units = [
storage
for storage in psa_net.storage_units.index
if storage not in flexible_storage_units
]
inflexible_loads = [
load for load in edisgo_obj.dsm.e_min.columns if load not in flexible_loads
]
if len(inflexible_cps) > 0:
hv_flex_dict["cp"] = (
(
hv_flex_dict["cp"]
- psa_net.loads_t.p_set.loc[:, inflexible_cps].sum(axis=1) / s_base
)
.round(20)
.clip(lower=0)
)
if len(inflexible_hps) > 0:
hv_flex_dict["hp"] = (
(
hv_flex_dict["hp"]
- psa_net.loads_t.p_set.loc[:, inflexible_hps].sum(axis=1) / s_base
)
.round(20)
.clip(lower=0)
)
if len(inflexible_storage_units) > 0:
hv_flex_dict["storage"] = (
hv_flex_dict["storage"]
- psa_net.storage_units_t.p_set.loc[:, inflexible_storage_units].sum(axis=1)
/ s_base
).round(20)
if len(inflexible_loads) > 0:
hv_flex_dict["dsm"] = (
hv_flex_dict["dsm"]
- psa_net.loads_t.p_set.loc[:, inflexible_loads].sum(axis=1) / s_base
).round(20)
count = (
len(flexible_loads)
+ len(flexible_storage_units)
+ len(flexible_hps)
+ len(flexible_cps)
+ len(pm["gen_nd"].keys())
)
for i in np.arange(len(opf_flex)):
pm["HV_requirements"][str(i + 1)] = {
"P": hv_flex_dict[opf_flex[i]][0],
"name": opf_flex[i],
"count": count,
}
def _build_timeseries(
psa_net,
pm,
edisgo_obj,
s_base,
flexible_cps,
flexible_hps,
flexible_loads,
flexible_storage_units,
opf_flex,
hv_flex_dict,
):
"""
Build timeseries dictionary in PowerModels network data format and add it to
PowerModels dictionary 'pm'. PowerModels' timeseries dictionary contains one
timeseries dictionary each for: gen, load, battery storage, electromobility, heat
pumps and dsm storage.
Parameters
----------
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
pm : dict
(PowerModels) dictionary.
edisgo_obj : :class:`~.EDisGo`
s_base : int
Base value of apparent power for per unit system.
flexible_cps : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all charging points that allow for flexible charging.
flexible_hps : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all heat pumps that allow for flexible operation due to an
attached heat storage.
flexible_loads : :numpy:`numpy.ndarray<ndarray>` or list
Array containing all flexible loads that allow for application of demand side
management strategy.
flexible_storage_units : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible storage units.
opf_flex : list
Flexibilities that should be considered in the optimization. Must be any
subset of ["curt", "storage", "cp", "hp", "dsm"].
hv_flex_dict : dict
Dictionary containing time series of HV requirement for each flexibility
retrieved from overlying_grid component of edisgo object.
"""
for kind in [
"gen",
"gen_nd",
"gen_slack",
"load",
"electromobility",
"heatpumps",
"dsm",
"HV_requirements",
]:
_build_component_timeseries(
psa_net,
pm,
s_base,
kind,
edisgo_obj,
flexible_cps,
flexible_hps,
flexible_loads,
flexible_storage_units,
opf_flex,
hv_flex_dict,
)
pm["time_series"]["num_steps"] = len(psa_net.snapshots)
def _build_component_timeseries(
psa_net,
pm,
s_base,
kind,
edisgo_obj=None,
flexible_cps=None,
flexible_hps=None,
flexible_loads=None,
flexible_storage_units=None,
opf_flex=None,
hv_flex_dict=None,
):
"""
Build timeseries dictionary for given kind and add it to 'time_series'
dictionary in PowerModels dictionary 'pm'.
Parameters
----------
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
pm : dict
(PowerModels) dictionary.
s_base : int
Base value of apparent power for per unit system.
kind : str
Must be one of ["gen", "gen_nd", "gen_slack", "load", "storage",
"electromobility", "heatpumps", "heat_storage", "dsm", "HV_requirements"].
edisgo_obj : :class:`~.EDisGo`
flexible_cps : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all charging points that allow for flexible charging.
flexible_hps : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all heat pumps that allow for flexible operation due to an
attached heat storage.
flexible_loads : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible loads that allow for application of demand side
management strategy.
flexible_storage_units : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible storage units.
opf_flex : list
Flexibilities that should be considered in the optimization.
hv_flex_dict : dict
Dictionary containing time series of HV requirement for each flexibility
retrieved from overlying grid component of edisgo object.
"""
pm_comp = dict()
solar_gens = edisgo_obj.topology.generators_df.index[
edisgo_obj.topology.generators_df.type == "solar"
]
wind_gens = edisgo_obj.topology.generators_df.index[
edisgo_obj.topology.generators_df.type == "wind"
]
disp_gens = edisgo_obj.topology.generators_df.index[
(edisgo_obj.topology.generators_df.type != "wind")
& (edisgo_obj.topology.generators_df.type != "solar")
]
if flexible_storage_units is not None:
inflexible_storage_units = [
storage
for storage in psa_net.storage_units.index
if storage not in list(flexible_storage_units)
]
flex_loads = np.concatenate((flexible_hps, flexible_cps))
inflexible_loads = [_ for _ in psa_net.loads.index if _ not in flex_loads]
if kind == "gen":
p_set2 = (psa_net.generators_t.p_set[disp_gens]).round(20)
q_set2 = (psa_net.generators_t.q_set[disp_gens]).round(20)
p_set = (
pd.concat(
[
p_set2,
psa_net.storage_units_t.p_set[inflexible_storage_units]
.clip(lower=0)
.round(20),
],
axis=1,
)
/ s_base
)
q_set = (
pd.concat(
[
q_set2,
psa_net.storage_units_t.q_set[inflexible_storage_units]
.clip(upper=0)
.round(20),
],
axis=1,
)
/ s_base
)
for comp in p_set.columns:
comp_i = _mapping(
psa_net,
edisgo_obj,
comp,
kind,
flexible_storage_units=flexible_storage_units,
)
pm_comp[str(comp_i)] = {
"pg": p_set[comp].values.tolist(),
"qg": q_set[comp].values.tolist(),
}
elif kind == "gen_nd":
p_set = (
psa_net.generators_t.p_set[
np.concatenate((solar_gens.values, wind_gens.values))
]
/ s_base
).round(20)
q_set = (psa_net.generators_t.q_set[p_set.columns] / s_base).round(20)
for comp in p_set.columns:
comp_i = _mapping(
psa_net,
edisgo_obj,
comp,
kind,
flexible_storage_units=flexible_storage_units,
)
pm_comp[str(comp_i)] = {
"pg": p_set[comp].values.tolist(),
"qg": q_set[comp].values.tolist(),
}
elif kind == "gen_slack":
p_set = (
psa_net.generators_t.p_set.loc[
:,
psa_net.generators_t.p_set.columns.str.contains("slack"),
]
/ s_base
)
q_set = psa_net.generators_t.q_set[p_set.columns] / s_base
for comp in p_set.columns:
comp_i = _mapping(
psa_net,
edisgo_obj,
comp,
kind,
flexible_storage_units=flexible_storage_units,
)
pm_comp[str(comp_i)] = {
"pg": p_set[comp].values.tolist(),
"qg": q_set[comp].values.tolist(),
}
elif kind == "load":
p_set = (
pd.concat(
[
psa_net.loads_t.p_set.loc[:, inflexible_loads],
-1
* psa_net.storage_units_t.p_set[inflexible_storage_units].clip(
upper=0
),
],
axis=1,
)
/ s_base
).round(20)
q_set = (
pd.concat(
[
psa_net.loads_t.q_set.loc[:, inflexible_loads],
-1
* psa_net.storage_units_t.q_set[inflexible_storage_units].clip(
lower=0
),
],
axis=1,
)
/ s_base
).round(20)
for comp in p_set.columns:
comp_i = _mapping(
psa_net,
edisgo_obj,
comp,
kind,
flexible_cps=flexible_cps,
flexible_hps=flexible_hps,
flexible_loads=flexible_loads,
flexible_storage_units=flexible_storage_units,
)
p_d = p_set[comp].values
q_d = q_set[comp].values
pm_comp[str(comp_i)] = {
"pd": p_d.tolist(),
"qd": q_d.tolist(),
}
elif kind == "electromobility":
if len(flexible_cps) > 0:
p_set = (
edisgo_obj.electromobility.flexibility_bands["upper_power"][
flexible_cps
]
/ s_base
).round(20)
e_min = (
edisgo_obj.electromobility.flexibility_bands["lower_energy"][
flexible_cps
]
/ s_base
).round(20)
e_max = (
edisgo_obj.electromobility.flexibility_bands["upper_energy"][
flexible_cps
]
/ s_base
).round(20)
for comp in flexible_cps:
comp_i = _mapping(
psa_net, edisgo_obj, comp, kind, flexible_cps=flexible_cps
)
pm_comp[str(comp_i)] = {
"p_max": p_set[comp].values.tolist(),
"e_min": e_min[comp].values.tolist(),
"e_max": e_max[comp].values.tolist(),
}
elif kind == "heatpumps":
if len(flexible_hps) > 0:
p_set = (edisgo_obj.heat_pump.heat_demand_df[flexible_hps] / s_base).round(
6
)
cop = edisgo_obj.heat_pump.cop_df[flexible_hps]
for comp in flexible_hps:
comp_i = _mapping(
psa_net, edisgo_obj, comp, kind, flexible_hps=flexible_hps
)
pm_comp[str(comp_i)] = {
"pd": p_set[comp].values.tolist(),
"cop": cop[comp].values.tolist(),
}
elif kind == "dsm":
if len(flexible_loads) > 0:
p_set = (edisgo_obj.dsm.p_max[flexible_loads] / s_base).round(20)
p_min = (edisgo_obj.dsm.p_min[flexible_loads] / s_base).round(20)
e_min = (edisgo_obj.dsm.e_min[flexible_loads] / s_base).round(20)
e_max = (edisgo_obj.dsm.e_max[flexible_loads] / s_base).round(20)
for comp in flexible_loads:
comp_i = _mapping(
psa_net, edisgo_obj, comp, kind, flexible_loads=flexible_loads
)
pm_comp[str(comp_i)] = {
"p_max": p_set[comp].values.tolist(),
"p_min": p_min[comp].values.tolist(),
"e_min": e_min[comp].values.tolist(),
"e_max": e_max[comp].values.tolist(),
}
if (kind == "HV_requirements") & (pm["opf_version"] in [3, 4]):
for i in np.arange(len(opf_flex)):
pm_comp[(str(i + 1))] = {
"P": hv_flex_dict[opf_flex[i]].round(20).tolist(),
}
pm["time_series"][kind] = pm_comp
def _mapping(
psa_net,
edisgo_obj,
name,
kind="bus",
flexible_cps=None,
flexible_hps=None,
flexible_loads=None,
flexible_storage_units=None,
):
"""
Map edisgo component to either bus ID or component ID that is used in PowerModels
dictionary 'pm'.
Parameters
----------
psa_net : :pypsa:`PyPSA.Network<network>`
:pypsa:`PyPSA.Network<network>` representation of network.
edisgo_obj : :class:`~.EDisGo`
name: str
Component name that is used in eDisGo object.
kind : str
If "bus", then bus ID that is used in PowerModels dictionary 'pm' and that
the component is connected to is returned. Else, component ID of the considered
component that is used in PowerModels dictionary 'pm' is returned.
Must be one of ["bus", "gen", "gen_nd", "gen_slack", "load", "storage",
"electromobility", "heatpumps", "heat_storage", "dsm"].
Default: "bus".
flexible_cps : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all charging points that allow for flexible charging.
flexible_hps : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all heat pumps that allow for flexible operation due to an
attached heat storage.
flexible_loads : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible loads that allow for application of demand side
management strategy.
flexible_storage_units : :numpy:`numpy.ndarray<ndarray>` or None
Array containing all flexible storage units.
"""
solar_gens = edisgo_obj.topology.generators_df.index[
edisgo_obj.topology.generators_df.type == "solar"
]
wind_gens = edisgo_obj.topology.generators_df.index[
edisgo_obj.topology.generators_df.type == "wind"
]
disp_gens = edisgo_obj.topology.generators_df.index[
(edisgo_obj.topology.generators_df.type != "wind")
& (edisgo_obj.topology.generators_df.type != "solar")
]
if flexible_storage_units is not None:
inflexible_storage_units = [
storage
for storage in psa_net.storage_units.index
if storage not in list(flexible_storage_units)
]
else:
inflexible_storage_units = None
if kind == "bus":
df = psa_net.buses
elif kind == "gen":
df2 = psa_net.generators.loc[disp_gens]
df = pd.concat([df2, psa_net.storage_units.loc[inflexible_storage_units]])
elif kind == "gen_nd":
df = psa_net.generators.loc[
np.concatenate((solar_gens.values, wind_gens.values))
]
elif kind == "gen_slack":
df = psa_net.generators.loc[(psa_net.generators.index.str.contains("slack"))]
elif kind == "storage":
df = psa_net.storage_units.loc[flexible_storage_units]
elif kind == "load":
flex_loads = np.concatenate((flexible_hps, flexible_cps))
if len(flex_loads) == 0:
df = pd.concat(
[psa_net.loads, psa_net.storage_units.loc[inflexible_storage_units]]
)
else:
df = pd.concat(
[
psa_net.loads.drop(flex_loads),
psa_net.storage_units.loc[inflexible_storage_units],
]
)
elif kind == "electromobility":
df = psa_net.loads.loc[flexible_cps]
elif (kind == "heatpumps") | (kind == "heat_storage"):
df = psa_net.loads.loc[flexible_hps]
elif kind == "dsm":
df = psa_net.loads.loc[flexible_loads]
else:
df = pd.DataFrame()
logging.warning("Mapping for '{}' not implemented.".format(kind))
idx = df.reset_index()[df.index == name].index[0] + 1
return idx
def _get_pf(edisgo_obj, pm, idx_bus, kind):
"""
Retrieve and return power factor from edisgo config files.
Parameters
----------
edisgo_obj : :class:`~.EDisGo`
pm : dict
(PowerModels) dictionary.
idx_bus : int
Bus index from PowerModels bus dictionary.
kind : str
Must be one of ["gen", "load", "storage", "hp", "cp"].
Returns
-------
(float, int)
"""
grid_level = pm["bus"][str(idx_bus)]["grid_level"]
pf = edisgo_obj.config._data["reactive_power_factor"][
"{}_{}".format(grid_level, kind)
]
sign = edisgo_obj.config._data["reactive_power_mode"][
"{}_{}".format(grid_level, kind)
]
if kind in ["gen", "storage"]:
if sign == "inductive":
sign = -1
else:
sign = 1
elif kind in ["load", "hp", "cp"]:
if sign == "inductive":
sign = 1
else:
sign = -1
return pf, sign
def _result_df(pm, component, variable, timesteps, index, s_base):
cols = [
pm["nw"]["1"][component][n]["name"]
for n in list(pm["nw"]["1"][component].keys())
]
data = [
[
pm["nw"][str(t)][component][n][variable] * s_base
for n in list(pm["nw"]["1"][component].keys())
]
for t in timesteps
]
return pd.DataFrame(index=index, columns=cols, data=data)